![Linkcom SlimDoorPhone 1 button Manual Download Page 13](http://html1.mh-extra.com/html/linkcom/slimdoorphone-1-button/slimdoorphone-1-button_manual_1923540013.webp)
Linkcom France
11 rue du Soleil Levant 92140 CLAMART
Copyright © 2012 – Linkcom – Tous droits réservés
13
dd
– command for
DAY
MODE
switching [2 digits]
nn
– command for
NIGHT
MODE
switching [2 digits]
Note:
The switchover to
Day/Night mode
remains set in unit even after line disconnection.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
47
e
Dialling mode
1
1
0
e
– operating mode of unit
e=0
selects
2-Group
mode
,
e=1
selects
Day/Night
mode
.
5.4
Time parameters
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
51
q
Number of rings before
pick-up
2
1
2
q
– Number of incoming call rings before a call is picked up. The number can be set from 1
to 9.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
52
d
Maximum call duration
2
1
4
d
– maximum time in minutes for which a call may last. This time can be
extended during a call by dialling Prolong Call digit from telephone
(
∗
or #). Time setting is per table.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
53
w
time between button
presses
2
2
2
w
– max. time [sec] between button presses [range 1-9]
-
relay closing
– if time between two next presses is bigger than
w
time, the code
is not evaluated correctly.
-
dialling
– if the button pressed is the first password number for switch closing, so
the choice is delayed by this
w
time
.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
54
z
On hook time before
new call
2
2
2
z
– time [sec] for which the unit will hang up, before repeat dialling (button pressing during
call or dialling, busy tone detection) [range 1-5]
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
55
z
Call start time
1
1
1
time
[min]
choice
0,5
0
1 - 9
1 - 9
15
∗
30
#
Summary of Contents for SlimDoorPhone 1 button