69
Equipment
Connection
Comments
ID
Setting parameters (group)
Vitosolic 2
3X1.25
Ó
1
aVG
3X2.25
Ó
2
aVG
At terminals 145 of the Vitosolic 200,
cores are interchangeable; see Vito-
solic installation instructions
7016 Type Vitosolic
Ó
2 (system configuration)
Two-way shut-off
valve and cylinder
primary pump (DHW
side)
2X8.12
1X2.N
1X1.
?
(see page 54)
For DHW heating in a cylinder primary
system; control both components from
terminal 2X8.12
By selecting the system dia-
grams
Cooling functions
NC-Box without mixer/extension kit natural cooling (NC)
Equipment
Connection
Comments
ID
Setting parameters (group)
NC-Box
without
mixer
2X8.6
Ó
X2.4
1X2.N
Ó
X2.3
1X1.
?Ó
X5.
?
7100
Cooling
Ó
1 (cooling)
Cooling with direct
heating circuit A1
2003 Remote control (option)
Ó
Yes (heating circuit A1)
7101 Cooling circuit
Ó
1 (heating circuit A1)
Cooling in heating
circuit with
mixer M2
3003 Remote control (option)
Ó
Yes (heating circuit M2)
7101 Cooling circuit
Ó
2 (heating circuit M2)
Cooling in heating
circuit with
mixer M3
4003 Remote control (option)
Ó
Yes (heating circuit M3)
7101 Cooling circuit
Ó
3 (heating circuit M3)
Cooling in a sepa-
rate cooling circuit
7101 Cooling circuit
Ó
4 (separate cooling circuit)
Installation instructions NC-Box
Installation sequence
Positioning of all terminals
(cont.)
5368 522 UAE
Installation