79
Equipment
Connection
Comments
ID
Setting parameters (group)
Mixer close
See the previous
screen
Observe parameter 701A
7015 Set external blocking/mixer
close
0
Ó
8 (system definition)
Swimming pool water heating
Applications with "External extension H1" can only be operated one at the time.
Note
■ Connect only the circulation pump for
swimming pool water heating
E
according to the following diagram. Do
not connect a filter circuit pump here.
■ Control of the swimming pool water
heating with KM BUS via the "External
extension H1".
■ The KM BUS cores are interchangea-
ble.
■ Contrary to the "External extension
H1" installation instructions, both devi-
ces are connected at plug
gÖ
.
Equipment
Connection
Comments
ID
Setting parameters (group)
Swimming pool
water heating
See the following
illustration
Requires a zero volt N/O contact,
breaking capacity AC 230V 0.1A
7010 Ext. Extension
Ó
Yes (system configuration)
7008 Swimming pool
Ó
Yes (system configuration)
Installation sequence
Connection of electrical components
(cont.)
5368 522 UAE
Installation