Energy statement
Calling up values to create the energy statement of the heat pump and the solar
heating system (if installed). It will be shown how much electrical energy has been
used to operate the system and how much heating energy has been transferred into
the heating system. These values are shown for the last 12 months.
Note
These values can only be displayed with
contractor access rights (see
page 107).
Access
■ Main menu
■ Information
■ Statistic
■ Energy calculation
■ Heat pump
e Electrical energy used [kWh] per
month
H Transferred heating energy [kWh] per
month for the heating system
Example
Determination of the electrical energy
used during last
March
with the current
date being the 12 January:
01 e: 140 H: 525
02 e: 510 H: 2080
03 e: 432 H: 1860 (values searched for last March)
04 e: 380 H: 1720
05 e: 000 H: 000
06 e: 000 H: 000
07 e: 000 H: 000
08 e: 000 H: 000
09 e: 000 H: 000
10 e: 000 H: 000
11 e: 000 H: 000
12 e: 000 H: 000
01 e: 000 H: 000
(current month; shown on the bottom
line)
Note
To achieve realistic data capture, param-
eter "Output" (5030) must be set up cor-
rectly.
The value must be checked and possibly
adjusted as follows:
■ Commissioning
■ Reset with "Standard display"
■ Activating the "Reset" function
Solar heating system operating
instructions (for energy state-
ment for the solar heating sys-
tem)
Troubleshooting
Control unit diagnostics
(cont.)