200
Setting parameters
Setting range
Standard
setting
Commission-
ing
External heat source
External heat source
Yes/No
No
Priority
Yes/No
Yes
Dual-mode temperature -50 to 50 °C
10 °C
External heat source for
DHW
Yes/No
No
DHW
Cylinder temperature,
DHW
10 to 70 °C
10 °C
Switching times, DHW
0 to 3
1
Min. temperature
5 to 60 °C
10 °C
Max. temperature
20 to 80 °C
60 °C
Hysteresis
1 to 10 K
7 K
Hysteresis booster
heater
2 to 30 K
10 K
Start optimisation,
DHW
Yes/No
No
Stop optimisation, DHW Yes/No
No
Auxiliary DHW function
Yes/No
No
Set DHW temperature
2
10 to 70 °C
60 °C
Temp. sensor 2
Yes/No
No
Booster heater
Yes/No
No
DHW with electric
power
Yes/No
Yes
Stop optimisation, DHW Yes/No
No
Auxiliary DHW function
Yes/No
No
Set DHW temperature
2
10 to 70 °C
60 °C
Temp. sensor 2
Yes/No
No
Booster heater
Yes/No
No
DHW with electric
power
Yes/No
Yes
Stop optimisation, DHW Yes/No
No
Auxiliary DHW function
Yes/No
No
Set DHW temperature
2
10 to 70 °C
60 °C
Commissioning/service reports
Control parameter report
(cont.)