146
Parameter
■ 6000
Operating instructions
Switching times, DHW
Parameter
■ 6001
Operating instructions
Min. temperature
Parameter
■ 6005
The minimum temperature prevents the
DHW temperature inside the DHW cyl-
inder from falling too low (frost protec-
tion).
When the actual temperature falls below
the min. temperature, the DHW cylinder
is heat up to that value plus hysteresis.
This is independent of the selected oper-
ating program.
If 2 cylinder temperature sensors are fit-
ted, only the top sensor will be used to
capture the temperature.
Access
■ "
Device settings
"
■ "
Programming
"
■ "
DHW
"
■
y
to
"Min. temp."
■
1
or
!
Standard setting
10 °C
Setting range
5 to 60 °C
Max. temperature
Parameter
■ 6006
Renewed heating will be prevented after this max. temperature has been reached
inside the DHW cylinder, until the temperature has dropped by at least 5 K.
DHW control settings
Cylinder temperature DHW
5368 522 UAE