161
■
"YES"
or
"NO"
■ As for heating circuit 2 and heating cir-
cuit 3
Standard setting
No
Setting range
Yes/No
Vitotrol 200 installation instruc-
tions
Heating curve level
Parameter
■ 2006 - HK A1
■ 3006 - HK M2
■ 4006 - HK M3
Separate setting of switching times for all
heating circuits A1, M2 and M3.
Operating instructions
Heating curve slope
Parameter
■ 2007 - HK A1
■ 3007 - HK M2
■ 4007 - HK M3
Separate setting of switching times for all
heating circuits A1, M2 and M3.
Operating instructions
Room hook-up slope
Parameter
■ 200A - HK A1
■ 300A - HK M2
■ 400A - HK M3
The slope for room temperature hook-up
can be selected, subject to a room tem-
perature sensor being installed and
room temperature hook-up being ena-
bled (see page 162).
The higher the selected value, the
greater the influence of the room tem-
perature.
Control settings, heating circuits
Activating the remote control
(cont.)
5368 522 UAE
Service