163
Parameter
■ 200E - HK A1
■ 300E - HK M2
■ 400E - HK M3
Limiting the set heating circuit flow tem-
perature to a maximum value.
Note
This parameter is unsuitable for limiting
the actual flow temperature (e.g. to pro-
tect underfloor heating circuits).
Access
■ "
Device settings
"
■ "
Programming
"
■ "
Heating circ. 1
" (heating circuit A1)
■
y
to
" Max. flow temp."
■
1
or
!
■ As for heating circuit 2 and heating cir-
cuit 3
Standard setting
40 °C
Setting range
10 to 70 °C
Control settings, heating circuits
Maximum flow temperature
5368 522 UAE
Service