CAUTION
•
DO NOT OPERATE THIS PUMP DRY!
•
Review instructions before operating.
•
Wear ear protection to reduce objectionable noise.
WARNING
•
Turn off power before servicing.
•
If fuel is spilled, avoid creating any source of ignition until
the fuel vapors have been cleaned up and removed.
APPLICATION
This pump is suitable for installations where the vertical distance
from the pump to the water level does not exceed 25 ft. In off-
PERFORMANCE
set installations, friction losses in the suction pipe must be taken
into consideration.
BASED ON 5’ SUCTION LIFT.
NOTE:
This trash pump can handle pumping stones, leaves,
mud and other debris of sizes up to the listed solids handling for
the pump and up to 25% of the fl ow by volume.
SAFETY
CAREFULLY READ THESE SAFETY
MESSAGES IN THIS MANUAL AND
ON PUMP.
Pump
Model
Pump
Size
Solids
Handling
Total Head in Feet
30
40
50
60
70
80
90
Capacity in U.S. Gallons per Minute
FTSP-2 2’’ x 2’’
1 1/8’’
198
194
180
145
110
75
40
FTSP-3 3’’ x 3’’
1 1/2 ‘‘
318
265
172
98
42
FTSP-4 4’’ x 4’’
2’’
616
500
400
280
190
120
45
Pump
Model
Total Head in Metres
9
12
15
18.5
21.5
23.5
27.5
Capacity in Litres per Minute
FTSP-2
750
735
680
550
415
285
150
FTSP-3
1205
1005
650
370
160
FTSP-4
2330
1890
1515
1060
720
455
170
FTSP SERIES SELF-PRIMING
TRASH PUMPS
OWNER'S MANUAL
BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.
SAFETY WARNINGS