I22124
Condition : Refrigerant is not effective.
I30081
0.5 (5.0)
0.4 (4.0)
0.3 (3.0)
0.2 (2.0)
MPa (kgf/cm
2
)
Pressure on low pressure side
Blower HI Zone
Blower LO Zone
MPa (kgf/cm
2
)
Pressure on HI
pressure side
0.5 (5.0)
1.0 (10.0)
1.5 (15.0)
2.0 (20.0)
1.06 (10.9)
0.27 (2.85)
0.22 (2.25)
0.2 (2.1)
0.14 (1.5)
1.2 (12.3)
1.25 (12.8)
1.32 (13.5)
–
HEATER & AIR CONDITIONER
REFRIGERANT
55–17
2332
Author:
Date:
2002 CAMRY REPAIR MANUAL (RM881U)
(9)
Defective compression compressor
Symptom
Probable cause
Diagnosis
Corrective Actions
Pressure too high on low high
pressure sides
Pressure too low to on high pres-
sure side
Internal leak in compressor
Compression failure
Leakage from valve damaged or
broken sliding parts
Repair or replace compressor
Gauge readings (Reference)