A62243
Air
E
F
A62244
Air
E
F
Battery
Ohmmeter
Continuity
B09131
Ohmmeter
No Continuity
B09132
A
B
Air
B09133
–
EMISSION CONTROL
EMISSION CONTROL SYSTEM (2AZ–FE)
12–9
1502
Author:
Date:
2002 CAMRY REPAIR MANUAL (RM881U)
(c)
Inspect the VSV operation.
(1)
Check that air flows with a little difficulty from ports
E to F.
(2)
Apply battery voltage across the terminals.
(3)
Check that air flows from port E to port F.
If operation is not as specified, replace the VSV.
5.
AIR CLEANER CAP SUB–ASSY
(a)
Inspect VSV for Canister Closed valve (CCV).
(1)
Using an ohmmeter, check that there is continuity
between the terminals.
Resistance: 24 – 30
Ω
at 20
C (68
F)
If there is no continuity, replace the VSV.
(2)
Using an ohmmeter, check that there is no continu-
ity between each terminal and the body.
If there is continuity, replace the VSV.
(3)
Check that air flows from ports A to B.