Input Parameters
This page shows the UPS line voltage input readings. This page will refresh automatically at a user-defined rate. To
change or view the current refresh rate setting, select “RemotEye III Management”
→
“HTTP Page Refresh Rates”
in the RemotEye III web interface.
Parameter #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Input Parameters
4300
input Power Factor
This field shows the present UPS
input power factor.
Input Rated Active Power (Watts)
This field shows the present UPS
input rated active power in
Watts.
Input Apparent Power (VA)
This field shows the present UPS
input apparent power in Volt-
Amps.
Input Rated Frequency (Hz)
This field shows the input rated
frequency of the UPS.
Input Active Power (Watts)
This field shows the present UPS
input active power in Watts.
Input Rated Current (Amps)
This field shows the input rated
current of the UPS in Amps.
Input Frequency (Hz)
This field shows the UPS input
frequency in Hz.
Input Current (Amps)
This field shows the present UPS
input current in Amps.
Input Current Percent (%)
This field shows the UPS input
current in percent.
Input Voltage Percent (%)
This field shows the UPS input
voltage in percent.
Input Rated Voltage (V)
This field shows the input rated
voltage of the UPS. This can be
changed by the administrator.
Object
Description
1600XP
4300
Input Power Supply Configuration
This field shows the present
power supply information at the
input for the UPS.
Input Line to Neutral Voltage (V)
This field shows the UPS input
Line to Neutral in VAC.
Input Number of Lines
This field shows the number of
input lines for the UPS.
input Voltage (V)
This field shows the UPS input
voltage in VAC.
Input Rated Line to Line Voltage (V)
This field shows the rated input
Line to Line voltage in VAC.
Input Rated Line to Neutral Voltage (V)
This field shows the rated input
line to neutral voltage in VAC.
Input Rated Power (Watts)
This field shows the input rated
power in Watts.
Input Rated Power (VA)
This field shows the input rated
power in VA.
Input Phase Check
This field shows the present
status of input phase check.
When enabled it detects phase
rotation error.
VIUV Detection Level (%)
This field shows the Voltage
Input Under-Voltage detection
level in percent.
VIOV Detection Level (%)
This field shows the Voltage
Input Over-Voltage detection
level in percent.