58
RemotEye III User Manual – 62330-005
4200FA/4300 Alarm/Trap Table
ID Alarm Occur Message
SNMP Trap Add
Level
SNMP Trap Remove
1
upsAlarmFault
upsTrapFault
Fault
upsTrapFaultClear
2
upsAlarmOpenFuse
upsTrapOpenFuse
Fault
upsTrapOpenFuseClear
3
upsAlarmCurrentLimitFault
upsTrapCurrentLimitFault
Fault
upsTrapCurrentLimitFaultClear
4
upsAlarmDCBusOverCurrent
upsTrapDCBusOverCurrent
Fault
upsTrapDCBusOverCurrentClear
5
upsAlarmDCOverVoltage
upsTrapDCOverVoltage
Fault
upsTrapDCOverVoltageClear
6
upsAlarmDCBusImbalance
upsTrapDCBusImbalance
Fault
upsTrapDCBusImbalanceClear
7
upsAlarmOutputUnderVoltage
upsTrapOutputUnderVoltage
Fault
upsTrapOutputUnderVoltageClear
8
upsAlarmOutputOverVoltage
upsTrapOutputOverVoltage
Fault
upsTrapOutputOverVoltageClear
9
upsAlarmHeatSinkOverheat
upsTrapHeatSinkOverheat
Fault
upsTrapHeatSinkOverheatClear
10
upsAlarmUPSOverload
upsTrapUPSOverload
Fault
upsTrapUPSOverloadClear
11
upsAlarmChargerOverVoltage
Fault
upsTrapChargerOverVoltage
Fault
Fault
upsTrapChargerOverVoltage
FaultClear
12
upsAlarmOutputOverCurrent
upsTrapOutputOverCurrent
Fault
upsTrapOutputOverCurrentClear
13
upsAlarmDCUnderVoltAtBoostUp
upsTrapDCUnderVoltAtBoostUp
Fault
upsTrapDCUnderVoltAtBoostUp
Clear
14
upsAlarmDCUnderVoltAtCharge
upsTrapDCUnderVoltAtCharge
Fault
upsTrapDCUnderVoltAtCharge
Clear
15
upsAlarmBypassOverheat
upsTrapBypassOverheat
Fault
upsTrapBypassOverheatClear
16
upsAlarmInputPhaseRotationError
upsTrapInputPhaseRotationError
Fault
upsTrapInputPhaseRotationErrorClea
r
17
upsAlarmBypassPhaseRotationErro
r
upsTrapBypassPhaseRotationError
Fault
upsTrapBypassPhaseRotationErrorCl
ear
18
upsAlarmWarning
upsTrapWarning
Warning
upsTrapWarningClear
19
upsAlarmInputOverVoltage
upsTrapInputOverVoltage
Warning
upsTrapInputOverVoltageClear
20
upsAlarmInputUnderVoltage
upsTrapInputUnderVoltage
Warning
upsTrapInputUnderVoltageClear
21
upsAlarmBatteryTestFailed
upsTrapBatteryTestFailed
Warning
upsTrapBatteryTestFailedClear
22
upsAlarmSystemTestFailed
upsTrapSystemTestFailed
Warning
upsTrapSystemTestFailedClear
23
upsAlarmBatteryLow
upsTrapBatteryLow
Warning
upsTrapBatteryLow
Clear
24
upsAlarmBatteryAtShutdownlevel
upsTrapBatteryAtShutdownlevel
Warning
upsTrapBatteryAtShutdownlevelClea
r
25
upsAlarmBatteryVoltageNotGood
upsTrapBatteryVoltageNotGood
Warning
upsTrapBatteryVoltageNotGoodClea
r
26
upsAlarmBatteryMCCBOff
upsTrapBatteryMCCBOff
Warning
upsTrapBatteryMCCBOff
Clear
27
upsAlarmBypass
upsTrapBypass
Warning
upsTrapBypassClear
Summary of Contents for RemotEye III
Page 1: ... ...
Page 117: ...116 RemotEye III User Manual 62330 005 Figure 62 RemotEye Save Log Utility Set Page ...