RemotEye III User Manual – 62330-005
137
Registers
Data Type
Size
Description
Units
Multiplier
Comments
30121
Unsigned Integer
16-Bit
Output Apparent Power (Part 1 of 2)
VA
X 1
Use this formula: (Register (30121) *
0x10000) + Register (30122)
30122
Unsigned Integer
16-Bit
Output Apparent Power (Part 2 of 2)
VA
X 1
30123
Unsigned Integer
16-Bit
Output Rated Apparent Power
KVA
X 1
30124
N/A
N/A
N/A
N/A
N/A
30125
Unsigned Integer
16-Bit
Output Rated Power Factor
PF
X 1
B
y
p
a
ss
P
a
ra
m
et
ers
30126
Unsigned Integer
16-Bit
Bypass Number of Phases
Phase
X 1
30127
Unsigned Integer
16-Bit
Bypass Voltage
Volts
X 1
30128
N/A
N/A
N/A
N/A
N/A
30129
N/A
N/A
N/A
N/A
N/A
30130
N/A
N/A
N/A
N/A
N/A
30131
N/A
N/A
N/A
N/A
N/A
30132
N/A
N/A
N/A
N/A
N/A
30133
N/A
N/A
N/A
N/A
N/A
30134
N/A
N/A
N/A
N/A
N/A
30135
N/A
N/A
N/A
N/A
N/A
30136
Unsigned Integer
16-Bit
Bypass Under Voltage Detection
%
X 1
30137
N/A
N/A
N/A
N/A
N/A
30138
Unsigned Integer
16-Bit
Bypass Under Voltage Recovery
%
X 1
30139
Unsigned Integer
16-Bit
Bypass Over Voltage Detection
Volts
X 1
30140
Unsigned Integer
16-Bit
Bypass Over Voltage Recovery
Volts
X 1
30141
Unsigned Integer
16-Bit
Bypass Current
Amps
X 0.1
30142
Unsigned Integer
16-Bit
Bypass Frequency
Hz
X 0.1
30143
N/A
N/A
N/A
N/A
N/A
30144
N/A
N/A
N/A
N/A
N/A
30145
Unsigned Integer
16-Bit
Bypass Apparent Power (Part 1 of 2)
VA
X 1
Use this formula: (Register (30145) *