3.4.1 General condition for straight pipe length
According to JEMIS032-1987, generally required straight pipe length for ultrasonic
flowmeter is defined as below.
Longer straight pipe length might be better to be choosen for ideal condition of
measurement.
L
≧
10D
Probe
L
≧
5D
L
≧
50D
10D
or more
L
≧
10D
L
≧
30D
D
1.5D or more
0.5D
or
more
L
≧
5D
L
≧
5D
L
≧
10D
L
≧
30D
When flow volume is adjusted
at the upstream valve.
L
≧
10D
When flow volume is adjusted
at the downstream valve.
P
L
≧
50D
Check valve
Gate valve
Upstream straight pipe length
Downstream straight pipe length
Section
90
゜
bend
T
Expanding
pipe
Various
valves
Pump
[Refer to JEMIS 032-1987.]
[D: pipe diameter]
Contracting
pipe
10D
or more
10D
or
more
Table 3.4.1-1