1-69
8. Thickness of pipe
Input pipe thickness by numeric button directly. Here for example, input “4.50mm”, then push
“
Enter
” key (F3 button) to proceed to next step.
Fig. 1.2.8-13 Pipe thickness input menu
9. Lining material
Select material of the lining from default choices or User Defined by direction or numeric button.
Here for example, select “
2:Epoxy
”, then push “
Select
” key (F3 button) to proceed next step.
Following sound speed is defined as
default listed material.
Table 1.2.8-3 Selectable items of lining
material
Fig. 1.2.8-14 Lining material selection menu
After you select material, you will see predefined sound speed, normally just proceed to next.
If you would like to select any un-listed materials, please select “
User Defined
” then enter actual
sound speed of the material later at the next extra menu.
Material
Sound speed
[m/s]
Epoxy
2000
Mortar
2500
Rubber
1900
PVC
(Poly Vinyl Chloride)
2280
P i p e C o n d i t i o n
T h i c k n e s s
4 . 5
0
m m
# 0 1 :
1 0 0 / S t e e l / 1 M
B a c k
C l e a r
E n t e r
Push
Enter
key
L i n i n g C o n d i t i o n
M a t e r i a l
1 : N o n e
2 :
E p o x y
3 : M o r t a r
4 : R u b b e r
5 : P V C
6 : U s e r D e f i n e d
# 0 1 :
1 0 0 / S t e e l / 1 M
B a c k
S e l e c t
Push
Select
key
Note:
Over ½ of pipe diameter is invalid value. (Max range: up to 100mm)
Summary of Contents for UFP-20
Page 1: ...Doc No KF08 002L Portable Ultrasonic Flowmeter UFP 20 Installation Operation Manual ...
Page 3: ... 2 The attachment of warning label is as follows Fig 1 2 Rear view of main unit Warning label ...
Page 8: ...1 Installation ...
Page 9: ......
Page 17: ......
Page 18: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 130: ...2 Operation ...
Page 131: ......
Page 182: ...3 Other ...
Page 183: ......
Page 193: ...3 8 3 2 4 Dimensions 1 Main Unit Fig 3 2 4 1 Main Unit Hand Strap ...