![Tokyo Keiki UFP-20 Installation & Operation Manual Download Page 154](http://html1.mh-extra.com/html/tokyo-keiki/ufp-20/ufp-20_installation-and-operation-manual_1125190154.webp)
2-21
(4) Fluid condition
Change fluid type, sound speed viscosity and so on.
Fig. 2.2.4-9 Fluid condition menu
1. Type
Press
Select
key (F3 button) and select item using direction button.
Press
Enter
key (F3 button) to confirm the selected item.
Table 2.2.4-10 Fluid type
Fluid type
Sound speed
[m/s]
Viscosity
[x10
-6
m
2
/s]
Density
[m
3
/kg] (*1)
Specific heat
[J/kgK] (*2)
Water
1460
1.20
1000.0
4184.0
Seawater
1510
1.00
1023.0
3930.0
Ethylene Glycol (50wt%)
1691
4.13
1066.0
3265.0
Glycerin
1923
1188.55
1261.3
580.0
Acetone
1190
0.407
790.5
516.0
User Defined
Input any value
between
500 to 9000
Input any value
between
0.01 to 9000
Input any value
between
100 to 9000
Input any value
between
0.0 to 999999.0
If you do not find fluid type, you can use
“User Defined” item.
F l u i d C o n d i t i o n
1 :
T y p e
W a t e r
2 : S o u n d S p e e d
1 4 6 0 m / s
3 : V i s c o s i t y
1 . 2 0 0 1 0
- 6
m
3
/ s
4 : D e n s i t y
1 0 0 0 . 0 k g / m
3
5 : S p e c i f i c H e a t
4 1 8 4 . 0 J / k g K
# 0 1 : 1 0 0 / S t e e l / 1 M
B a c k
S e l e c t
Note:
(*1) When meter type item is selected mass meter or energy meter, it have to input density.
(*2) When meter type item is selected energy meter, it have to input specific heat.
Summary of Contents for UFP-20
Page 1: ...Doc No KF08 002L Portable Ultrasonic Flowmeter UFP 20 Installation Operation Manual ...
Page 3: ... 2 The attachment of warning label is as follows Fig 1 2 Rear view of main unit Warning label ...
Page 8: ...1 Installation ...
Page 9: ......
Page 17: ......
Page 18: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 130: ...2 Operation ...
Page 131: ......
Page 182: ...3 Other ...
Page 183: ......
Page 193: ...3 8 3 2 4 Dimensions 1 Main Unit Fig 3 2 4 1 Main Unit Hand Strap ...