Table 1.2.2-1 Connection terminals, indications and key functions
Specification or settings may limit the functions.
Please be careful of the polarization of each line.
Name
Connection
Icon on
display
Instruction
SENSOR1
UP, DN
LEMO
Connection to primary path transducers or thickness gauge.
Connect upstream transducers to "UP" side.
Connect to downstream transducers to "DN" side.
SENSOR2
UP, DN (*1)
LEMO
Connection to secondary path transducers
Connect upstream transducers to "UP" side.
Connect to downstream transducers to "DN" side.
This connection requires in case of 2 path measurement.
AC power supply
The icon indicates remain level of battery.
This icon means full charged.
The icon indicates remain level of battery.
Charging is recommended.
Power-IN/
battery
The icon indicates remain level of battery.
Battery charge required if battery icon indicated as left.
Within 20min power might be off. (*2)
USB port
USB
The icon indicates capable USB memory
Temperature
port
12 Core
4 temperature input can be achieved with temperature junction
box.
Analog output
2 Core
Analog output
Power button
Power control key
Function button
F1 ~ F3 key will be assigned variable functional key
Shift button
Shift Key for 2
nd
menu
Contrast
adjustment
With shift button and direction key Contrast-Bright control can be
adjustable.
Direction button
Selection of direction
Numeric button
Use numeric when input data
Flowmeter mode
Massmeter mode
Meter type
Heatmeter mode
Totalizing
Totalizing function activated
Logging function appointed
Blinking during logging function activated
Logging
Not available any logging area
Error
R * / D * / E*
R : No Receiving echo warning
D : Disturbance error warning
E : Parameter error
Enough echo receiving during thickness / sound speed
measurement
Thickness
/ sound speed
measurement
No receiving echo during thickness / sound speed measurement
(*1) 2 path / 2 channel measurement system is an option.
(*2) Remain time until power off depends on component or measurement status.
Summary of Contents for UFP-20
Page 1: ...Doc No KF08 002L Portable Ultrasonic Flowmeter UFP 20 Installation Operation Manual ...
Page 3: ... 2 The attachment of warning label is as follows Fig 1 2 Rear view of main unit Warning label ...
Page 8: ...1 Installation ...
Page 9: ......
Page 17: ......
Page 18: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 130: ...2 Operation ...
Page 131: ......
Page 182: ...3 Other ...
Page 183: ......
Page 193: ...3 8 3 2 4 Dimensions 1 Main Unit Fig 3 2 4 1 Main Unit Hand Strap ...