Chapter 22: Remote Monitoring Commands
– 746 –
variable
– The object identifier of the MIB variable to be sampled.
Only variables of the type etherStatsEntry.n.n may be sampled.
Note that etherStatsEntry.n uniquely defines the MIB variable, and
etherStatsEntry.n.n defines the MIB variable, plus the
etherStatsIndex. For example, 1.3.6.1.2.1.16.1.1.1.6.1 denotes
etherStatsBroadcastPkts, plus the etherStatsIndex of 1.
interval
– The polling interval. (Range: 1-31622400 seconds)
absolute
– The variable is compared directly to the thresholds at
the end of the sampling period.
delta
– The last sample is subtracted from the current value and
the difference is then compared to the thresholds.
threshold
– An alarm threshold for the sampled variable.
(Range: 0-2147483647)
event-index
– The index of the event to use if an alarm is triggered.
If there is no corresponding entry in the event control table, then no
event will be generated. (Range: 0-65535)
name
– Name of the person who created this entry. (Range: 1-127
characters)
D
EFAULT
S
ETTING
1.3.6.1.2.1.16.1.1.1.6.1 - 1.3.6.1.2.1.16.1.1.1.6.52
Taking delta samples every 30 seconds,
Rising threshold is 892800, assigned to event 0
Falling threshold is 446400, assigned to event 0
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
•
If an event is already defined for an index, the entry must be deleted
before any changes can be made with this command.
•
If the current value is greater than or equal to the rising threshold, and
the last sample value was less than this threshold, then an alarm will be
generated. After a rising event has been generated, another such event
will not be generated until the sampled value has fallen below the rising
threshold, reaches the falling threshold, and again moves back up to
the rising threshold.
•
If the current value is less than or equal to the falling threshold, and
the last sample value was greater than this threshold, then an alarm
will be generated. After a falling event has been generated, another
such event will not be generated until the sampled value has risen
above the falling threshold, reaches the rising threshold, and again
moves back down to the failing threshold.
Summary of Contents for SSE-G2252
Page 42: ...44 General IP Routing on page 627...
Page 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Page 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Page 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Page 1007: ...Chapter 33 Address Table Commands 1019...
Page 1137: ...Chapter 38 Quality of Service Commands 1150...