Chapter 14: Basic Administration Protocols
Simple Network Management Protocol
– 412 –
W
EB
I
NTERFACE
To configure an SNMP group:
1.
Click Administration, SNMP.
2.
Select Configure Group from the Step list.
3.
Select Add from the Action list.
macNotificationTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.138
This trap is sent when there are
changes of the dynamic MAC
addresses on the switch.
lbdDetectionTrap
1.3.6.1.4.1.259.
10.1.17.
10.1.39.2.1.0.14
1
This trap is sent when a loopback
condition is detected by LBD.
lbdRecoveryTrap
1.3.6.1.4.1.259.
10.1.17.
10.1.39.2.1.0.14
2
This trap is sent when a recovery is
done by LBD.
sfpThresholdAlarmWarnTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.189
This trap is sent when the SFP’s
monitored value is not within alarm/
warning thresholds.
udldPortShutdownTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.192
This trap is sent when the port is shut
down by UDLD.
userAuthenticationFailureTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.199
This trap will be triggered if
authentication fails.
userAuthenticationSuccessTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.200
This trap will be triggered if
authentication is successful.
loginTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.201
This trap is sent when user logs in.
logoutTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.202
This trap is sent when user logs out.
fileCopyTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.208
This trap is sent when file copy is
executed.
If the copy action is triggered by the
system, the login user information
(trapVarLoginUserName/
trapVarSessionType/
trapVarLoginInetAddressTypes/
trapVarLoginInetAddres) will be a null
value.
userauthCreateUserTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.209
This trap is sent when a user account is
created.
userauthDeleteUserTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.210
This trap is sent when a user account is
deleted.
userauthModifyUserPrivilegeTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.211
This trap is sent when user privilege is
modified.
cpuGuardControlTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.213
This trap is sent when CPU utilization
rises above the high-watermark the
first time or when CPU utilization rises
from below the low-watermark to
above the high-watermark.
cpuGuardReleaseTrap
1.3.6.1.4.1.259.10.1.39.2.1.0.214
This trap is sent when CPU utilization
falls from above the high-watermark to
below the low-watermark.
a. These are legacy notifications and therefore must be enabled in conjunction with the corresponding traps on the SNMP
Configuration menu.
Table 14-10: Supported Notification Messages (Continued)
Model
Level
Group
Summary of Contents for SSE-G2252
Page 42: ...44 General IP Routing on page 627...
Page 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Page 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Page 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Page 1007: ...Chapter 33 Address Table Commands 1019...
Page 1137: ...Chapter 38 Quality of Service Commands 1150...