Chapter 38: Quality of Service Commands
– 1141 –
committed-burst
- Committed burst size (BC) in bytes.
(Range: 0-16000000 at a granularity of 4k bytes)
excess-burst
- Excess burst size (BE) in bytes.
(Range: 0-1600000 at a granularity of 4k bytes)
conform-action
- Action to take when rate is within the CIR and
BC. (There are enough tokens in bucket BC to service the packet,
packet is set green).
exceed-action
- Action to take when rate exceeds the CIR and BC
but is within the BE. (There are enough tokens in bucket BE to
service the packet, the packet is set yellow.)
violate-action
- Action to take when rate exceeds the BE. (There
are not enough tokens in bucket BE to service the packet, the
packet is set red.)
transmit
- Transmits without taking any action.
drop
- Drops packet as required by exceed-action or violate-action.
new-dscp
- Differentiated Service Code Point (DSCP) value.
(Range: 0-63)
D
EFAULT
S
ETTING
None
C
OMMAND
M
ODE
Policy Map Class Configuration
C
OMMAND
U
SAGE
•
You can configure up to 16 policers (i.e., class maps) for ingress ports.
•
The
committed-rate
cannot exceed the configured interface speed, and
the
committed-burst
and
excess-burst
cannot exceed 16 Mbytes.
•
The srTCM as defined in RFC 2697 meters a traffic stream and
processes its packets according to three traffic parameters –
Committed Information Rate (CIR), Committed Burst Size (BC), and
Excess Burst Size (BE).
•
The PHB label is composed of five bits, three bits for per-hop behavior,
and two bits for the color scheme used to control queue congestion. A
packet is marked green if it doesn't exceed the CIR and BC, yellow if it
does exceed the CIR and BC, but not the BE, and red otherwise.
•
The meter operates in one of two modes. In the color-blind mode, the
meter assumes that the packet stream is uncolored. In color-aware
mode the meter assumes that some preceding entity has pre-colored
the incoming packet stream so that each packet is either green, yellow,
or red. The marker (re)colors an IP packet according to the results of
the meter. The color is coded in the DS field [RFC 2474] of the packet.
•
The behavior of the meter is specified in terms of its mode and two
token buckets, C and E, which both share the common rate CIR. The
maximum size of the token bucket C is BC and the maximum size of the
token bucket E is BE.
Summary of Contents for SSE-G2252
Page 42: ...44 General IP Routing on page 627...
Page 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Page 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Page 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Page 1007: ...Chapter 33 Address Table Commands 1019...