Chapter 26: Interface Commands
– 949 –
S
YNTAX
[no] power-save
C
OMMAND
M
ODE
Interface Configuration (Ethernet, Ports 1-48)
C
OMMAND
U
SAGE
•
IEEE 802.3 defines the Ethernet standard and subsequent power
requirements based on cable connections operating at 100 meters.
Enabling power saving mode can reduce power used for cable lengths
of 60 meters or less, with more significant reduction for cables of 20
meters or less, and continue to ensure signal integrity.
•
Power saving mode only applies to the Gigabit Ethernet ports using
copper media.
•
Power savings can be enabled on Gigabit Ethernet RJ-45 ports.
•
The power-saving methods provided by this switch include:
•
Power saving when there is no link partner:
Under normal operation, the switch continuously auto-negotiates to
find a link partner, keeping the MAC interface powered up even if no
link connection exists. When using power-savings mode, the switch
checks for energy on the circuit to determine if there is a link
partner. If none is detected, the switch automatically turns off the
transmitter, and most of the receive circuitry (entering Sleep Mode).
In this mode, the low-power energy-detection circuit continuously
checks for energy on the cable. If none is detected, the MAC
interface is also powered down to save additional energy. If energy
is detected, the switch immediately turns on both the transmitter
and receiver functions, and powers up the MAC interface.
•
Power saving when there is a link partner:
Traditional Ethernet connections typically operate with enough
power to support at least 100 meters of cable even though average
network cable length is shorter. When cable length is shorter, power
consumption can be reduced since signal attenuation is proportional
to cable length. When power-savings mode is enabled, the switch
analyzes cable length to determine whether or not it can reduce the
signal amplitude used on a particular link.
N
OTE
:
Power savings can only be implemented on Gigabit Ethernet ports
using twisted-pair cabling. Power-savings mode on a active link only works
when connection speed is 1 Gbps, and line length is less than 60 meters.
Summary of Contents for SSE-G2252
Page 42: ...44 General IP Routing on page 627...
Page 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Page 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Page 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Page 1007: ...Chapter 33 Address Table Commands 1019...
Page 1137: ...Chapter 38 Quality of Service Commands 1150...