CXD5602 User Manual
-
449/1010
-
3.9.12.3.150
{0x5528} INT_CLEAR_MAIN_AD Details
Table SCU (Sensor Control Unit)-258
Local Address: 0x5528
Register Type: WO (write only)
Reset Value: 0x00000000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
LP
A
D
C_
A
LM
O
S
T_
F
U
LL3
LP
A
D
C_
A
LM
O
S
T_
F
U
LL2
LP
A
D
C_
A
LM
O
S
T_
F
U
LL1
Bits
Name
Type Reset Value Description
31..3
Reserved
WO 0x00000000 Reserved
2
LPADC_ALMOST_FULL3 WO 0x0
1
LPADC_ALMOST_FULL2 WO 0x0
0
LPADC_ALMOST_FULL1 WO 0x0
Interrupt clear of Math Function Event 0.
When the SPI is selected, the interrupt is
cleared by the register of the SPI Slave.