CXD5602 User Manual
-
482/1010
-
3.9.12.3.186
{0x5680} PWM_TIMER01 details
When the PWM is not used, PWM generator can be used as a timer. In this case, counter values within the timer
can be read.
Table SCU (Sensor Control Unit)-294
Local Address: 0x5680
Register Type: RO (read only)
Reset Value: 0x00000000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TIMER1
TIMER0
Bits
Name
Type Reset Value
Description
31..16
TIMER1
RO
0x0000
Counter value of PWM1
15..0
TIMER0
RO
0x0000
Counter value of PWM0
3.9.12.3.187
{0x5684} PWM_TIMER23 Details
When the PWM is not used, PWM generator can be used as a timer. In this case, counter values within the timer
can be read.
Table SCU (Sensor Control Unit)-295
Local Address: 0x5684
Register Type: RO (read only)
Reset Value: 0x00000000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TIMER3
TIMER2
Bits
Name
Type Reset Value
Description
31..16
TIMER3
RO
0x0000
Counter value of PWM3
15..0
TIMER2
RO
0x0000
Counter value of PWM2
Summary of Contents for CXD5602
Page 1: ...CXD5602 User Manual 1 1010 CXD5602 User Manual ...
Page 36: ...CXD5602 User Manual 36 1010 2 3 Block Diagram Figure Block Diagram 1 CXD5602 Block Diagram ...
Page 144: ...CXD5602 User Manual 144 1010 GNSS_RAMMODE_SEL 0x3F000FFF SRAM GNSS BB 0 5 ON ...