EM330D User Manual
A Special Purpose Inverter for Hoisting
88
No.
Function
Range
Unit Default Type
FE-05
Analog Terminal Input
Logic
Ones place: Input terminal VS
0
:
VS is on at high level input
1
:
VS is on at low level input
Tens place: Input terminal IS
0
:
IS is on at high level input
1
:
IS is on at low level input
Hundreds place: Input terminal VF
0
:
VF is on at high level input
1
:
VF is onat low level input
Thousands place: Input terminal IF
0: IF is on at high level input
1: IF is on at low level input
0000
〇
When FE-04 selects numeric input mode, FE-05 sets the effective logic of input signal.
For instance: set FE-04 ones place=1.
If FE-05 ones place=0, terminal VS is on at high level input. If FE-05 ones place=1,
terminal VS is on at low level input.
No.
Function
Range
Unit
Default
Type
FE-17
X1 Off Delay Time
0.00
~
300.00
S
0.0
〇
FE-18
X2 Off Delay Time
0.00
~
300.00
S
0.0
〇
Terminal X1 or X2 off delay time refers to how long it will delay for inverter to execute the
function of X1 or X2.