EM330D User Manual
A Special Purpose Inverter for Hoisting
59
7 Parameter Description
7.1
Group F0: General Parameters
No.
Function
Range
Unit
Default Type
F0-00
Speed Reference
Input Monitoring
Frequency: 0.00
~
Fmax
Speed: 0
~
F*Customer defined
scaling
Hz
rpm
0.00
0.0
×
F0-01
F0
-
00 and F0
-
01 are optional and for reference only. Their parameters are the setting value
of present drive mode. Symbol (-) shall be displayed if the value is negative. When the
reference input control mode is different, the data reflected by F0-00/F0-01 is also different.
Speed Reference Input Monitoring
The unit of F0-00/F0-01 is Hz or rpm which indicates that the present control object is the
motor speed, its value is the present setting objective value of speed. When objective value
is reverse input, then symbol (-) shall be displayed.
No.
Function
Range
Unit
Default
Type
F0-02
Drive Control Mode 0: Specialized hoisting control
0
〇
F0-02=0
Specialized hoisting control
No.
Function
Range
Unit
Default
Type
F0-03
Setting Input Control
Mode
0: Speed input
1: Torque input
(
Not used
)
0
〇
F0-03=0
Input control mode is speed input, the input is frequency.
No.
Function
Range
Unit
Default
Type
F0-04
Start/Stop
Control
Options
0: Keypad
1: Terminal
2: RS485
1
〇
F0-05
Terminal
Start/Stop
Control Options
0: RUN-Run, F/R-Forward/Reverse
1: RUN-Run, F/R- Reverse
2: RUN-NO forward,
Xi-NC stop, F/R-NO reverse
3: RUN-NO run,
Xi-NC stop,
F/R- Forward/Reverse
1
〇