Xi=26
Brake detection input
For starting Brake detection macro of tower crane, conducting Brake detection
automatically. The inspection process takes 30 seconds.
Xi=27~50
Not apply to hoisting
Xi=51
External device fault input
After the terminal receives external device fault signal in operation, inverter stops and
enters fault status. The default is NO input of external fault, and it can be set as NC input by
terminal positive/negative logic of FE-01.
No.
Function
Range
Unit
Default
Type
F2-12
Multi-function Output Terminal Y1
See Table 7-1
Functions
of
Numeric
Multi-function Output Terminals
9
〇
F2-13
Multi-function Output Terminal Y2
1
〇
F2-14
Relay Output Terminal R1
24
〇
EM330D provides 3 programmable output terminals including 2 multi-function output
terminals and 1 relay output terminal. There are 0
~
32 program codes, user can define
output variables of terminals.
2 multi-function output terminals are in OC output mode, output common port is connected
to COM. When selected program code is enabled, the electronic switch is ON, and when it
is disabled, the electronic switch is OFF. OC can be powered either internally or externally,
as shown in Figure 7-6(a) and 7-6(b) respectively. If it is externally powered, the voltage
range is required to be within 8~24V.
+3.3V
COM
EM330D
PLC
Y1.Y2
+24V
24V
Relay
+3.3V
COM
EM330D
PLC
Y1.Y2
+24V
24V
Relay
+
-
DC
(a)Internal Power supply
(b)External Power supply
Figure 7-6 Power Supply Modes of Programmable Terminals