![Sinee EM330D-011-3B User Manual Download Page 100](http://html1.mh-extra.com/html/sinee/em330d-011-3b/em330d-011-3b_user-manual_1280542100.webp)
EM330D User Manual
A Special Purpose Inverter for Hoisting
100
11.3
Connecting Cable
Since all brake unit and braking resistors work at a high voltage (>400VDC) in a
non-continuous working status, please select applicable cable. See Table 11-2 for
specifications of main circuit cable, and take the cable which meets the insulation and
cross-section requirements.
Table 11-2 Cable for Braking Unit and Braking Resistor
Model No.
Average Brake Current
I
av
(A)
Peak Brake Current
I
max
(A)
Cross-section of Copper
Cable (mm
2
)
BR100-045
45
75
6
BR100-160
75
150
10
BR100-315
120
300
16
Soft cable possesses a better flexibility, so copper cable, soft heat-proof cable or
flame-proof cable is suggested because the cable may contact the equipment with high
temperature.The distance between braking unit and inverter shall within 2m. Otherwise, the
cable on DC side shall be twisted and shielded with magnetic ring to reduce radiation and
induction.
Refer to
User Manual of BR100 Braking Unit