Group F2: Input/Output Terminal Parameters
No.
Function
Range
Unit
Default
Type
F2-00
Multi-function Input Terminal
X1-RUN
See Table 6-1
Functions of Numeric
Multi-function Input Terminals
1
〇
F2-01
Multi-function Input Terminal
X2-F/R
2
〇
F2-02 Multi-function Input Terminal X3-D1
3
〇
F2-03 Multi-function Input Terminal X4-D2
4
〇
F2-04 Multi-function Input Terminal X5-D3
5
〇
F2-05
Multi-function Input Terminal
X6-FRS
9
〇
F2-06
Multi-function Input Terminal
X7-RST
10
〇
F2-07 Not Used
F2-08 VS Input Function Defining
0
〇
F2-09 IS Input Function Defining
0
〇
F2-10 VF Input Function Defining
0
〇
F2-11 IF Input Function Defining
0
〇
F2-12 Multi-function Output Terminal Y1
See Table 6-2
Functions of Numeric
Multi-function Output
Terminals
9
〇
F2-13 Multi-function Output Terminal Y2
1
〇
F2-14 Relay Output Terminal R1
24
〇
F2-15 Not Used
F2-16 Analog Output Terminal M0
See Table 6-3
F2-16
~
F2-20
Analog Output Full Scale
%
0
〇
F2-17 Analog Output Terminal M1
%
6
〇
F2-18~ F2-21 Not Used
F2-22 M0 Output Lower Limit
0.00
~
100.00
%
0.00
●
F2-23 M0 Output Upper Limit
0.00
~
100.00
%
100.00
●
F2-24 M0 Output Gain
0.00
~
300.00
%
300.00
●
F2-25 M1 Output Lower Limit
0.00
~
100.00
%
0.00
●
F2-26 M1Output Upper Limit
0.00
~
100.00
%
100.00
●
F2-27 M1 Output Gain
0.00
~
300.00
%
300.00
●
Table 6-1 Functions of Numeric Multi-function Input Terminals
No.
Function
No.
Function
0
Disabled
23
Run Command Input 1
1
RUN-run
24
Switching Input Control Mode to Speed
Control Mode
2
F/R Forward/Reverse Command
25
Switching Input Control Mode to Toruqe
Control Mode