EM330D User Manual
A Special Purpose Inverter for Hoisting
52
FE-03 X2 Input Delay
0.00
~
300.00
S
0.00
〇
FE-04
Analog Input Signal
Options
Ones place: VS input signal options
0
:
Analog signal input
1
:
Numeric signal input
Tens place: IS input signal options
0
:
Analog signal input
1
:
Numeric signal input
Hundreds place: VF input signal options
0: Analog signal input
1: Numeric signal input
Thousands place: IF input signal options
0: Analog signal input
1: Numeric signal input
0000
〇
FE-05
Analog Terminal Input
Logic
Ones place: Input terminal VS
0: VS is on at high level input
1: VS is on at low level input
Tens place: Input terminal IS
0: IS is on at high level input
1: IS is on at low level input
Hundreds place: Input terminal VF
0: VF is on at high level input
1: VF is on at low level input
Thousands place: Input terminal IF
0: IF is on at high level input
1: IF is on at low level input
0000
〇
FE-06 Output Signal Type
Ones place: Y1 output type
0
:
Level signal, 1
:
Pulse signal
Tens place: Y2 output type
0
:
Level signal, 1
:
Pulse signal
Hundreds place: R1 output type
0
:
Level signal, 1
:
Pulse signal
000
〇
FE-07
Terminal Output Logic
Control
Ones place: Y1 output logic control
0
:
Positive logic
1
:
Neginive logic
Tens place: Y2 output logic control
0
:
Positive logic
1
:
Neginive logic
Hundreds place: R1output logic control
0
:
Positive logic
1
:
Neginive logic
000
〇
FE-08 Virtual Terminal Options
Ones place: Terminals Y1/Y2/R1
0: Actual output terminal
1: Virtual output terminal
000
〇