EM330D User Manual
A Special Purpose Inverter for Hoisting
45
C0-11
C0-12 Output Current Percentage 0.00
~
300.00
%
×
C0-13
Effective Output Current
Value
0.0
~
3000.0
A
×
C0-14 Output Voltage Percentage
0.00
~
200.00
%
×
C0-15
Effective Output Voltage
Value
0.0
~
660.0
V
×
C0-16 DC Bus Voltage
0
~
1200
V
×
C0-17
~
C0-18
Not Used
C0-19 Program Operation Section 1
~
7
×
C0-20
Running Time of Present
Section
of
Program
Operation
0.0
~
6000.0
S/min
×
C0-21 Output Power
0.0
~
3000.0
kW
×
C0-22
~
C0-25
Not Used
C0-26 Input Terminal Status
X7 X6
X5
X4
X3
X2
X1
×
0
0
0
0
0
0
0
C0-27 Output Terminal Status
*
*
*
*
R1
Y2
Y1
×
0
0
0
0
0
0
0
C0-28 VS Input Monitor
0-10000
×
C0-29 IS Input Monitor
0-10000
×
C0-30 VF Input Monitor
0-10000
×
C0-31 IF Input Monitor
0-10000
×
6.2.7
Group E0: Fault Parameters
No.
Function
Trip and Parameter Description
Unit
Default
Type
E0-00
Fault Trips
00: No fault
SC: Drive Short Circuit/EMC
HOC: Instantaneous overcurrent
HOU: Instantaneous overvoltage
SOC: Stable overcurrent
SOU: Stable overvoltage
SLU: Stable undervoltage/SOFT
ILP: Input Phase Loss
OL: Overload
OH: Overheating
OLP: Output Phase Loss
0
◇