EM330D User Manual
A Special Purpose Inverter for Hoisting
87
Options of Input Terminal Logic
No.
Function
Range
Unit Default Type
FE-01
Terminal
Input
Positive/Negative
Logic
X7
X6
X5
X4
X3
X2
X1
00000000
〇
0
0
0
0
0
0
0
0: Positive Logic. On at 0V/Off at 24V
1: Negative Logic. Off at 0V/ On at 24V
FE-01=0
Positive logic, multi-function terminal is on at 0V, and off at 24V.
FE-01=1
Negative logic, multi-function terminal is off at 0V, and on at 24V.
The function is used for matching the logic of external device.
Analog Input Signal Options and Multi-function Terminal Extension
No.
Function
Range
Unit Default Type
FE-04
Analog
Input
Signal Options
Ones place: VS input signal options
0: Analog signal input
1: Numeric signal input
Tens place: IS input signal options
0: Analog signal input
1: Numeric signal input
Hundreds place: VF input signal options
0: Analog signal input
1: Numeric signal input
Thousands place: IF input signal options
0: Analog signal input
1: Numeric signal input
0000
〇
FE-04 ones place=0
Analog voltage signal VS input
FE-04 ones place =1
Utilized as multi-function input terminal
FE-04 tens place =0
Analog current signal IS input
FE-04 tens place =1
Utilized as multi-function input terminal
FE-04 hundreds place =0
Analog voltage signal VF input
FE-04 hundreds place =1
Utilized as multi-function input terminal
FE-04 thousands place =0
Analog current signal IF input
FE-04 thousands place =1
Utilized as multi-function input terminal
FE-04 is equivalent to 4 additional multi-function input terminals.