EM330D User Manual
A Special Purpose Inverter for Hoisting
54
F0-17 Upper Limit Frequency
55.00Hz
F0-20 Stop Mode Options
Coast to stop
1
F0-27 Menu Mode Options
Advanced menu
1
F1-01 Motor Rated Power
Set as what stated on the motor nameplate Set as per the motor
F1-03 Motor Rated Current
Set as what stated on the motor nameplate Set as per the motor
F1-05 Motor Rated Speed
Set as what stated on the motor nameplate Set as per the motor
F1-06 Motor Wiring Mode
Set as what stated on the motor nameplate Set as per the motor
F2-02 Multi-function Input Terminal X3
Preset speed terminal 1
3
F2-03 Multi-function Input Terminal X4
Preset speed terminal 2
4
F2-04 Multi-function Input Terminal X5
Preset speed terminal 3
5
F2-05 Multi-function Input Terminal X6
Preset speed terminal 4
6
F2-06 Multi-function Input Terminal X7
Fault resume
10
F2-08 VS Input Function Defining
The default is 0.When connecting to
GPS, please set as external device fault
input(51)
0
F2-10 VF Input Function Defining
External brake detection input
26
F2-12 Multi-function Input Terminal Y1
Inverter fault output
9
F2-13 Multi-function Input Terminal Y2
External brake detection output remind
27
F2-14 Relay Output Terminal R1
External brake control
24
F3-00 Preset Speed 1
Preset speed 2
25.00 Hz
F3-02 Preset Speed 3
Preset speed 3
35.00 Hz
F3-06 Preset Speed 7
Preset speed 4
45.00 Hz
F3-14 Preset Speed 15
Preset speed 5
55.00 Hz
F3-24 DC Brake Start Frequency at Stop
4.00Hz
F3-25 DC Brake Propotion at Stop
100.00%
F3-27 DC Brake Time at Stop
DC brake disabled
0.0S
F8-04 VS Filter Time
0.0S
F8-06 VF Filter Time
0.0S
F9-12 FDT1 Increasing Threshold
Y1,Y2, R1 or R2 is on when the output
Frequency Reach the threshold
2.00Hz
F9-13 FDT1 Decreasing Threshold
Y1,Y2, R1 or R2 is off when the output
Frequency Reach the threshold
9.50Hz
F9-24 Start-up Delay
3.00S
F9-30 Undervoltage Detection Scaling
75.00%
Fb-00
Frequency (Running Up) for
disengaging the external brake
3.00Hz
Fb-01
Frequency (Running Down) for
disengaging the external brake
3.00Hz
Fb-02
Delay time before the external
brake is disengaged
0.3S
Fb-03
Delay time after the external brake
is disengaged
0.3S
Fb-04
Frequency (Running Up) for
engaging the external brake
3.00Hz