EM330D User Manual
A Special Purpose Inverter for Hoisting
57
F2-06 Multi-function Input Terminal X7
Fault resume
10
F2-12 Multi-function Input Terminal Y1
Defined as inverter fault
9
F2-14 Relay Output Terminal R1
Defined as FDT1
2
F3-00 Preset Speed 1
Preset speed 2
38.00 Hz
F3-02 Preset Speed 3
Preset speed 3
50.00 Hz
F9-12 FDT1 Increasing Threshold
The external brake will be disengaged
when output frequency increases to the
setting value of F9-12
1.00 Hz
F9-13 FDT2 Decreasing Threshold
The external brake will be engaged when
output frequency reduced to the setting
value of F9-13
3.00 Hz
FC-19 Overvoltage Control Options
Overvoltage stall prohibited, and dynamic
brake enabled
0010
FC-28 Disabled Trips 1
Disable input phase loss trip
01000000
Fd-01 Voltage 1
4.00%
Fd-02 Voltage 2
9.00%
Fd-03 Voltage 3
15.00%
Fd-04 Voltage 4
25.00%
Fd-08 Frequency 4
20.00%
Remarks:
1.
Defaults of F4-28=8 Application Macros for Trolleying of Tower Crane as shown
in the table above.
2.
Users can define the range of those parameters based on real needs if the defaults
may not meet the application needs.
6.3.4
Applications Micro for Construction Lift
No.
Function
Description
Default
F0-02 Drive Control Mode
Special control for hoisting
0
F0-04 Start/Stop Control Selection
External terminals control start/stop
1
F0-05 Terminal Start/Stop Control Selection
Forward when terminal RUN is on.
Reverse when terminal F/R is on.
1
F0-06 Regular Speed Setting Mode
Primary numeric frequency setting
0
F0-07 Priamry Numeric Setting Frequency
Preset speed 1
15.00Hz
F0-09 Acceleration Time
Acceleration time
6.00S
F0-10 Deceleration Time
Deceleration time
2.00S
F0-14 Carrier Frequency
1.000kHz
F0-27 Menu Selection
Advanced menu
1
F2-02 Multi-function Input Terminal X3
Preset speed terminal 1
3
F2-06 Multi-function Input Terminal X7
Fault resume
10
F2-12 Multi-function Output Terminal Y1
Y1 is on at fault
9
F2-14 Relay Output Terminal R1
External brake control
24
F3-00 Preset Speed 1
Preset speed 2
50.00Hz
F9-24 Start-up Delay