EM330D User Manual
A Special Purpose Inverter for Hoisting
42
2
Output Frequency Detection Range FDT1
(Enabled at running)
19
Current Limit
3
Output Frequency Detection Range FDT2
(Enabled at running)
20
Frequency Zero Speed Detection
(Output Frequency Detection)
4
Output Frequency Detection Range FDT1
(Disabled at JOG)
21
Not Used
5
Output Frequency Detection Range FDT2
(Disabled at JOG)
22
Motor 2 Enabled
6
Forward/Reverse(Enabled at running)
23
Set running time is up
7
Frequency Input/Output Balance
(Enabled at running)
24
External Brake Device Control(For hoisting
only)
8
JOG
25
Not Used
9
Inverter Fault
26
Inverter is ready for running
10
Upper Limit Frequency Reached
27
External Brake Device Check Reminding
11
Lower Limit Frequency Reached
28~32 Not Used
12-16 Not Used
Table 6-3 F2-16~F2-20 Analog Outputs Full Scales
No.
Signal
Full Scale
(
100.0%
)
No.
Signal
Full Scale
(
100.0%
)
6
Output Current Inverter Rated Current
13
Not used
7
Output Voltage Inverter Rated Voltage
14
+10V
+10V
8
VP
10.00V
15
PID Input
PID Maximum Scale
9
VS
10.00V
16
PID Feedback
PID Maximum Scale
10 VF
10.00V
17-18 Not Used
11 IS
20mA
19
DC Bus Voltage
DC Bus Voltage at 1.5times
Rated Input Voltage
12 IF
20mA
20
Output Frequency Inverter Rated Frequency
6.2.4
Group F3: Preset Speed Operation Parameters
No.
Function
Range
Unit
Default
Type
F3-00 Preset Speed 1
0.00
~
Fmax
Hz
50.00
●
F3-01 Preset Speed 2
0.00
~
Fmax
Hz
5.00
●
F3-02 Preset Speed 3
0.00
~
Fmax
Hz
10.00
●
F3-03 Preset Speed 4
0.00
~
Fmax
Hz
15.00
●
F3-04 Preset Speed 5
0.00
~
Fmax
Hz
20.00
●
F3-05 Preset Speed 6
0.00
~
Fmax
Hz
25.00
●
F3-06 Preset Speed 7
0.00
~
Fmax
Hz
30.00
●
F3-07 Preset Speed 8
0.00
~
Fmax
Hz
35.00
●
F3-08 Preset Speed 9
0.00
~
Fmax
Hz
40.00
●
F3-09 Preset Speed 10
0.00
~
Fmax
Hz
45.00
●