EM330D User Manual
A Special Purpose Inverter for Hoisting
51
0: Enabled
,
1: Disabled, *: Not used
FC-30 Disabled Trips 3
* Ol1 SOFT SIE
SrE
SFE STP EEU
00000000
〇
0 0
0
0
0
0
0
0
0: Enabled, 1: Disabled, *: Not used
FC-31
Overcurrent Stall
Integral Time
0.00
~
300.00
mS
10.00
●
6.2.11
Group Fd: Auxiliary Parameters
No.
Function
Range
Unit
Default
Type
Fd-00 Not Used
Fd-01 Voltage 1
0.00
~
100.00
%
1.00
●
Fd-02 Voltage 2
0.00
~
100.00
%
4.00
●
Fd-03 Voltage 3
0.00
~
100.00
%
10.00
●
Fd-04 Voltage 4
0.00
~
100.00 , Ue=100.0%
%
16.00
●
Fd-05 Frequency 1
0.00
~
Frequency 2
Fbase=100.0%
%
1.00
●
Fd-06 Frequency 2
Frequency 1~ Frequency 3
%
4.00
●
Fd-07 Frequency 3
Frequency 2
~
Frequency 4
%
10.00
●
Fd-08 Frequency 4
Frequency 3
~
100.00
%
16.00
●
Fd-09~ Fd-19 Not Used
Fd-20 CPUB Software Version
X.XX
X.XX
X
Fd-21 Inverter Rated Power
0.40
~
480.00
kW
XXXX
X
Fd-22 Inverter Rated Voltage
60
~
660
V
XXX
X
Fd-23 Inverter Rated Current
0.1
~
1500.0
A
XXXX
X
Fd-24 Inverter Running Time
User monitoring
HOUR
XXXX
X
Fd-25 Inverter Running Time
User monitoring
min
XXXX
X
Fd-26 Running Time Control
0:Disabled 1:Enabled
0
-
Fd-27 Set Running Time
0
~
65535
HOUR
0
-
Fd-28~Fd-29 Not Used
-
Fd-30 Keypad Software Version
X.XX
X.XX
X
Fd-31 CPUA Software Version
X.XX
X.XX
X
6.2.12
Group FE: Terminal Function User Defined Parameters
No.
Function
Range
Unit
Default
Type
FE-00 Numeric Input Filter Times 0
~
100, 1=0.50mS
10
〇
FE-01
Terminal Input Positive/
Negative Logic
X7
X6
X5
X4
X3
X2
X1
00000000
〇
0
0
0
0
0
0
0
0: Positive Logic On at 0V/Off at 24V
1: Negative Logic Off at 0V/ On at 24V
FE-02 X1 Input Delay
0.00
~
300.00
S
0.00
〇