F0-06=2
Setting frequency is set by the voltage of analog terminal VS.
F0-06=3
Setting frequency is set by the current of analog terminal IS.
F0-06=4~10
Not used
1. The default of analog voltage input VS, VF is 0
~
10V.
2. The default of analog current input is 4
~
20mA.
No.
Function
Range
Unit
Default
Type
F0-07
Primary Numeric Frequency Setting
0.00
~
Fmax
Hz
15.00
●
F0-07
The
primary numeric frequency setting value is set by F0-07, and its range: 0.00
~
Fmax
★
The value of F0-07 can be edited directly by pressing
or
to edit in running
preparation and running status.
1. When reverse is permitted, inverter will judge present running direction based on
the setting of F0-08 and the status of terminal F/R. If F0-08=1, and terminal F/R is
on, then inverter runs forward.
2. Switch any two of output cables (U, V, and W) of inverter to make the inverter forwards
in the same direction as the expected running direction of motor, or set F0-08=1.
No.
Function
Range
Unit
Default
Type
F0-09
Acceleration Time 1
0.00
~
600.00
S/min
6.00
●
F0-10
Deceleration Time 1
0.00
~
600.00
S/min
2.00
●
Acceleration time is the time taken for the output frequency to rise from 0Hz up to
maximum frequency Fmax set by F0-16. Deceleration time is the time taken for the output
frequency to drop from Fmax down to 0Hz, which are not relevant to forward and reverse.
As shown in Figure 7-3.
t1
Output
Frequency(Hz)
Fmax
Time(S)
t2
Output
Frequency(Hz)
Fmax
Time(S)
(
a
)
Acceleration Time 1
(
b
)
Deceleration Time 1
Figure 7-4 Acceleration/Deceleration Time