EM330D User Manual
A Special Purpose Inverter for Hoisting
49
1:
Enabled
when
frequency and current
reached simultaneously
Fb-28
Current for disengaging the external brake
10.00
~
150.00
%
60.00
〇
6.2.10
Group FC: Operation Control Parameters
No.
Function
Range
Unit
Default
Type
FC-00
Acceleration/Decelerati
on
Mode
0: Linear mode
1: Not used
0
〇
FC-01
Proportion of
Acceleration S Curve
0.0
~
50.0
%
30.0
〇
FC-02
Proportion of
Deceleration S Curve
0.0
~
50.0
%
30.0
〇
FC-03 Fan Control
0: Run at power-on
1: Run at start-up
1
〇
FC-04 Fan Delay Time
0.00
~
600.00
S
30.00
●
FC-05 Not Used
FC-06
Resume previous
working status at
power-on
0: Not Resume
1: Resume
0
〇
FC-07 Current Stall Control
0: Disabled
1: Not used
2: Enabled
0
〇
FC-08 Stall Current
50.00
~
180.00
%
150.00
〇
FC-09 Not Used
FC-10
Energy Saving
Operation
Options
0: Disabled
1: Enabled
0
〇
FC-11
Initial Frequency of
Energy Saving
Operation
10.00
~
600.00/10.0
~
600.0
Hz
20.00
〇
FC-12
Energy Current
Detecting Range
20.00
~
80.00
%
40.00
〇
FC-13
Energy Saving Delay
Start Time
0.01
~
60.00
S
0.50
〇
FC-14
Energy Saving
Permitted Range
60.00
~
100.00
%
80.00
〇
FC-15 Output Voltage
5.00
~
100.00
%
100.00
●
FC-16 Brake Duty Ratio
5.00
~
100.00
%
80.00
〇