EM330D User Manual
A Special Purpose Inverter for Hoisting
37
6.2
Parameter Tables
Section 1 General Parameters
6.2.1
Group F0
:
General Parameters
No.
Function
Range
Unit
Default
Type
F0-00(L) Speed Reference Input
Monitoring
Frequency: 0.00
~
Fmax
Speed: 0
~
F*Customer defined scaling
Hz
rpm
0.00
X
F0-01(H)
F0-02
Drive Control Mode
0: Specialized hoisting control
0
〇
F0-03
Setting Input Control
Mode
0: Speed input
1: Torque input
(
Not used
)
0
〇
F0-04
Start/Stop Control
Options
0: Keypad
1: Terminal
2: RS485
1
〇
F0-05
Terminal Start/Stop
Control Options
0: RUN-Run
,
F/R-Forward/Reverse
1: RUN-Run
,
F/R- Reverse
2: RUN-NO forward, Xi-NC stop,
F/R-NO reverse
3: RUN-NO run
,
Xi-NC stop
,
F/R- Forward/Reverse
1
〇
F0-06
Regular Speed Setting
Mode
0: Primary numeric frequency
1: VP
2: VS
3: IS
4~10: Not used
0
〇
F0-07
Primary Numeric
Frequency Setting
0.00
~
Fmax
Hz
15.00
●
F0-08
Motor Running
Direction
0: Forward
1: Reverse
0
●
F0-09
Acceleration Time 1
0.00
~
600.00
S/min
6.00
●
F0-10
Deceleration Time 1
0.00
~
600.00
S/min
2.00
●
F0-11
Jog Numeric Frequency 0.00
~
Fmax
Hz
5.00
●
F0-12
Jog Acceleration Time
0.00
~
600.00
S/min
15.00
●
F0-13
Jog Deceleration Time
0.00
~
600.00
S/min
15.00
●
F0-14
Carrier Frequency
1.000
~
16.000
kHz
1.000
●
F0-15
Customer Defined V/F
Scaling
0: Automatic torque boost
1~10: Fixed torque boost curve
11~20: Oil pump motor boost curve
21~30: Synchronous motor boost curve
31~34: Blower/water pump boost curve
35: Customer defined V/F curve scaling
35
●