EM330D User Manual
A Special Purpose Inverter for Hoisting
44
Control 2
0
0
0
0
0
0
0
1
0
:
No Display
,
1
:
Display *: Not used
F4-15
Monitor
Reference
Options
*
Iq
Est.Slip Est.Spd
*
Sync-
Freq.
Inp.
Freq.
Outp.
Freq.
11111111
〇
1
1
1
1
1
1
1
1
0: Absolute Value
,
1: +/- *: Not used
F4-16
LCD Language
Options
0: Chinese
,
1: English
0
〇
F4-17
Not Used
F4-18
If parameters
change with
inverter’s
working status
0: Unchanged
1: Changed
1
〇
F4-19
Parameter
Setting Display
0
~
575
514
●
F4-20
Parameters
displayed in the
1
st
row in
operation
0
~
575
512
●
F4-21
~
F4-27
Not Used
F4-28
Application
Macros Options
0: General Purpose Inverter
6: Crane hoisting application macros
7: Crane slewing application macros
8: Crane trolleying application macros
9: Construction lift application macros
9
〇
Remarks:
1.
F4-28: Application macros, the default is F4-28=9(Construction lift application
macros), see 6.3 to set parameter default as per applications.
6.2.6
Group C0: Parameters of Monitoring Function
No.
Function
Range
Unit
Default
Type
C0-00
Output Frequency
0.00
~
Fup/0.0
~
Fup
Hz
×
C0-01
C0-02
Input Frequency
0.00
~
Fmax/0.0
~
Fmax
Hz
×
C0-03
C0-04
Synchronous Frequency
0.00
~
Fup/0.0
~
Fup
Hz
×
C0-05
C0-06~ C0-07 Not Used
C0-08 Estimated
Feedback
Frequency
00.00
~
Fup/0.0
~
Fup
Hz
×
C0-09
C0-10 Estimated Slip Frequency
0.00
~
Fup/0.0
~
Fup
Hz
×