EM330D User Manual
A Special Purpose Inverter for Hoisting
38
F0-16
Maximum Frequency
Fmax:20.00
~
600.00
Hz
50.00
〇
F0-17
Upper Limit Frequency Fup:Fdown
~
Fmax
Hz
50.00
〇
F0-18
Lower Limit Frequency Fdown:0.00
~
Fup
Hz
0.00
〇
F0-19
Start Mode Options
0: Normal start
1: Speed search start(Not used)
0
〇
F0-20
Stop Mode Options
0: Ramp to stop
1: Coast to stop
0
〇
F0-21
JOG
+/-
Function Setting
0: Jog running
1: Positive/Negative input switching
2: Not used
0
〇
F0-22
Speed Monitoring
Options
0: Frequency Hz
1: Speed rpm
0
●
F0-23
Customer Defined
Scaling
0.01
~
600.00
30.00
●
F0-24
F/R Control Mode
0: Reverse permitted
1: Reverse prohibited
0
〇
F0-25
F/R Deadband
0.00
~
600.00
S
0.00
〇
F0-26
Primary Speed Setting
Mode
0: Regular speed setting mode
1: Special speed setting mode
2: Not used
0
〇
F0-27
Menu Mode Options
0: Basic menu mode
1: Advanced menu mode
1
〇
F0-28
Default Control
0: Disabled
1: Defaults reset
0
〇
F0-29
Parameter Setting
Control
0: Parameter set permitted
1: Parameter lock 0
2: Parameter lock 1
0
〇
F0-30
Inverter Model
0: Model G 1: Model P
0
〇
F0-31
User Password
0
~
65535
XXXXX
〇
6.2.2
Group F1:Motor Parameters
No.
Function
Range
Unit
Default
Type
F1-00 Motor Type
0: AC induction motor
1: Not used
0
〇
F1-01 Motor Rated Power
0.40
~
480.00
kW
XXXX
〇
F1-02 Motor Rated Voltage
60
~
660
V
XXX
〇
F1-03 Motor Rated Current
0.1
~
1500.0
A
XXXX
〇
F1-04 Motor Rated Frequency
20.00
~
600.00
Hz
XXXX
〇
F1-05 Motor Rated Speed
1
~
30000
rpm
XXXX
〇
F1-06 Motor Wiring Mode
0:Y 1: Δ
X
〇
F1-07 Motor Rated Power Factor
0.50
~
0.99
X
〇