Description
3.4 Motors and multi-motor drives that can be operated
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
31
3.4
Motors and multi-motor drives that can be operated
Siemens motors that can be operated
You can connect standard induction motors to the inverter.
You can find information on further motors on the Internet:
Motors that can be operated
https://support.industry.siemens.com/cs/ww/en/view/100426622
Third-party motors that can be operated
You can operate standard asynchronous motors from other manufacturers with the inverter:
NOTICE
Insulation failure due to unsuitable third-party motor
A higher load occurs on the motor insulation in inverter mode than with line operation.
Damage to the motor winding may occur as a result.
•
Please observed the notes in the System Manual "Requirements for third-party motors"
Further information is provided on the Internet:
Requirements for third-party motors
https://support.industry.siemens.com/cs/ww/en/view/79690594
Multi-motor operation
Multi-motor operation involves simultaneously operating several motors from one inverter.
For standard induction motors, multi-motor operation is generally permissible.
Additional preconditions and restrictions relating to multi-motor operation are available on the
Internet:
Multi-motor drive (