Advanced commissioning
7.8 Setpoints
SIMATIC ET 200pro FC-2 converter
132
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
Parameter
Description
Setting
p1076[0…n]
CI: Supplementary setpoint
scaling
Signal source for scaling the supplementary setpoint
Factory setting: 0
r2050[0…11]
CO: PROFIdrive PZD re-
ceive word
Connector output to interconnect the PZD received from the fieldbus
controller in the word format.
[1] Most standard telegrams receive the speed setpoint as receive word
PZD02.
Further information
For further information refer to the function diagrams 2468, 9360 and 3030 of the List
Manual.
7.8.3
Motorized potentiometer as setpoint source
Function description
The "Motorized potentiometer" function emulates an electromechanical potentiometer. The
output value of the motorized potentiometer can be set with the "higher" and "lower" control
signals.
Figure 7-16 Motorized potentiometer as setpoint source