Advanced commissioning
7.8 Setpoints
SIMATIC ET 200pro FC-2 converter
134
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
Parameter
Description
Setting
p1048
MOP ramp-down time [s]
MOP ramp-down time:
Factory setting: 10 s
r1050
Motorized potentiometer,
setpoint after the ramp-
function generator
Motorized potentiometer, setpoint after the ramp-function generator
p1070[0…n]
CI: Main setpoint
Signal source for the main setpoint
The factory setting depends on the Control Unit.
With PROFIBUS or PROFINET interface: [0] 2050[1]
Without PROFIBUS or PROFINET interface: [0] 755[0]
p1071[0…n]
CI: Main setpoint scaling
Signal source for scaling the main setpoint
Factory setting: 1
r1073
CO: Main setpoint active
Displays the active main setpoint
p1075[0…n]
CI: Supplementary setpoint
Signal source for the supplementary setpoint
Factory setting: 0
p1076[0…n]
CI: Supplementary setpoint
scaling
Signal source for scaling the supplementary setpoint
Factory setting: 0