background image

 

 

 

 

DUOX PLUS  

SKYLINE KITS 

4-12W 

 

 

Cod. 970285I 

Summary of Contents for DUOX PLUS SKYLINE

Page 1: ...DUOX PLUS SKYLINE KITS 4 12W Cod 970285I ...

Page 2: ...PROGRAMMING 9 4 1 DUOX PLUS Monitors 9 4 2 DUOX PLUS Telephones 9 This document presents the basic concepts to install and program the KIT For more information download the technical information datasheets and manuals from FERMAX website by searching for the product reference or the manual code http www fermax com Entry Panel o 970049C Skyline Panel DUOX Amplifier V40 Esp Eng Fr De Po Power Supply...

Page 3: ...anguage configuration 0 Spanish 1 English 2 French 3 Dutch Flemish 4 German 5 Catalan 6 Valencian 7 Balearic 8 Portuguese 9 Basque 10 Galician 11 Greek 12 Polish 13 Czech 14 Slovak 15 Turkish 16 Chinese 17 Persian Farsi 18 Arabic 19 Norwegian 20 Finnish 21 Swedish 22 Danish 23 Icelandic 24 Russian 25 Italian 26 Hindi 27 Hungarian 28 Hebrew 29 Croatian 30 62 Bell 63 DISABLED ...

Page 4: ...DUOX PLUS SKYLINE KITS 4 12L 4 1 3 Flush Box and Panel Mounting Templates for Skyline Panel cardholder can be found in the following link https www fermax com intl en tools cardholder designs ...

Page 5: ...5 2 SCHEMATICS DISTANCES 2 1 Distribution up to 2 risers 2 2 Cascade Daisy Chain up to 4 risers ...

Page 6: ...ded Area mm 0 2 1 Diameter mm 0 52 1 15 AWG 24 18 Description Distance max m 1 riser 2 4 risers A B Entry Panel PSU First Floor 55 25 C Distance between Floors 3 D Connection point Home Terminal 25 Standard Copper cable Parallel Cross cable UTP Multi core cables are compatible with DUOX PLUS system ...

Page 7: ...n is higher a dedicated power supply must be installed It might be necessary to add an additional power supply in case of additional monitors in an apartment or if home terminals chosen are DDA monitors For best operation it is recommended to use the same cable cross section for the entire installation It is not recommended to double the pairs as it can affect the good operation of the system 3 2 ...

Page 8: ...DUOX PLUS SKYLINE KITS 4 12L 8 3 3 Entry Panel Wiring electric door lock wiring using external power supply ...

Page 9: ...med once the monitor address is programmed the red LED will turn off 4 2 DUOX PLUS Telephones The telephone will not function until it has been programmed Programming is done from the panel activated as master Press the Entry Panel s SW1 button 3 consecutive times quickly After 2 seconds a confirmation tone is heard beep beep and the master panel is activated ...

Page 10: ...ermax com Website http www fermax com Telephone number 96 317 80 00 96 317 80 18 96 378 88 26 Email fermax fermax com sales fermax com Website http www fermax com FERMAX ELECTRONICA S A U Avenida Tres Cruces 133 46017 Valencia Spain FERMAX ELECTRONICA S A U Avenida Tres Cruces 133 46017 Valencia Spain FERMAX ELECTRONICA S A U Avenida Tres Cruces 133 46017 Valencia Spain ...