Advanced commissioning
7.8 Setpoints
SIMATIC ET 200pro FC-2 converter
136
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
7.8.4
Fixed speed as setpoint source
In many applications after switching on the motor, all that is needed is to run the motor at a
constant speed or to switch between different speeds.
Example: After it has been switched on, a conveyor belt only runs with two different
velocities.
Interconnecting the fixed speeds with a main setpoint
Figure 7-18 Fixed speeds as setpoint source
Table 7- 17 Setting the fixed speed as a setpoint source
Parameter
Remark
p1070 = 1024
Main setpoint
Interconnecting the main setpoint with fixed speeds.