Advanced commissioning
7.7 Safe Torque Off (STO) safety function
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
121
7.7.3.4
Configuring safety functions
Procedure
1.
Go online.
2.
Select the "Safety Integrated" function.
3.
Select "Change settings".
4.
Select "Basic functions via onboard terminals":
You have configured the safety functions.
❒
Additional safety function configurations are described in the "Safety Integrated" Function
Manual.
Manuals for your inverter (Page 272)
Parameter Description
p0010 = 95 Drive commissioning parameter filter
Safety Integrated commissioning
p9601
Enable functions integrated in the drive (factory setting: 0000 bin)
0 hex
None of the safety functions has been released
1 hex
Basic functions via onboard terminals has been enabled
p9761
Enter a password (factory setting: 0000 hex)
Permissible passwords lie in the range 1 … FFFF FFFF.
p9762
New password
p9763