Appendix 1 Parameter list
Parameter List
156
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User setting
value
Reference
page
P.154
Modbus communication data
format
0~5
1
4
P62
P.155 Over torque detection level
0~200%
0.1%
0%
P114
P.156 Over torque detection time
0~60s
0.1s
1s
P114
P.157
External terminals filter
adjusting function
0~200ms
1ms
4ms
P115
P.158
External terminal power
enable
0, 1
1
0
P116
P.159
energy-saving control
function
0, 1
1
0
P116
P.160 Reserved
P.161
Multi-function display
selection
0~9, 11~13,
19~21
1
0
P116
P.162 Middle frequency 2
0~650Hz, 9999
0.01Hz
9999
P53
P.163
Output voltage 2 of middle
frequency
0~100%
0.1%
0
P53
P.164 Middle frequency 3
0~650Hz, 9999
0.01Hz
9999
P53
P.165
Output voltage 3 of middle
frequency
0~100%
0.1%
0
P53
P.166 Middle frequency 4
0~650Hz, 9999
0.01Hz
9999
P53
P.167
Output voltage 4 of middle
frequency
0~100%
0.1%
0
P53
P.168 Middle frequency 5
0~650Hz, 9999
0.01Hz
9999
P53
P.169
Output voltage 5 of middle
frequency
0~100%
0.1%
0
P53
P.170 PID function selection
0, 1, 2
1
0
P117
P.171
PID feedback control method
selection
0, 1
1
0
P117
P.172 PID proportion Gain
1~100
1
20
P117
P.173 PID integration Gain
0~100s
0.1s
1s
P117
P.174 PID differential Gain
0~1000ms
1ms
0 ms
P117