Introduction of Shihlin Inverter
Introduction of Inverter
26
3.6.2 Power cable specification/pressing connection terminals specification
Inverter Type
Power Cable Specification
(PVC cables standard)
Pressing connection terminal
specification (used by power cables)
Power supply terminal
(R/L1- S/L2- T/L3)
Loading terminal
(U/T1-V/T2-W/T3)
Power supply
terminal
Loading
terminal
Crimping
terminal
(mm
2
)
Tightening
torque
(Kgf.cm)
Crimping
terminal
(mm
2
)
Tightening
torque
(Kgf.cm)
SS2-021-0.4K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-021-0.75K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-021-1.5K
2.5
18
2.5
18
2-4
2-4
SS2-021-2.2K
4
18
4
18
5.5-4
2-4
SS2-023-0.4K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-023-0.75K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-023-1.5K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-023-2.2K
4
18
2.5
18
3.5-4
2-4
SS2-023-3.7K
4
18
4
18
5.5-4
5.5-4
SS2-043-0.4K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-043-0.75K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-043-1.5K
2.5
12.2
2.5
12.2
2-3.5
2-3.5
SS2-043-2.2K
2.5
18
2.5
18
2-4
2-4
SS2-043-3.7K
2.5
18
2.5
18
2-4
2-4
SS2-043-5.5K
4
18
2.5
18
5.5-4
2-4