Parameter Description
Parameter Description
129
increase or regenerative status.
To avoid backlash, temporarily stop the acceleration/deceleration. Set the acceleration/deceleration
stopping frequency and time in P.229 to P.233.
Note: When setting up backlash compensation, acceleration /deceleration time only in part time longer.
●
Acceleration/deceleration interrupted for waiting function
If P.229=2 and start the acceleration/deceleration interrupted for waiting function, when accelerate
to the frequency setted by P.230, it will keep the frequency for some time setted by P.231, and then
accelerate again to the target frequency; when decelerate to the frequency setted by P.232, it will
keep the frequency for some time setted by P.233, and then decelerate again to the target frequency.